Issue
- Monitoring software is reporting intermittent
loss_of_syncfor a single FCP adapter:
NetApp Fibre Channel Adapter node2/2c on cluster1 has reported a synchronization loss, placing the adapter into warn state.This adapter has lost synchronization a total of 1565.0 times. This is commonly caused by link failures.- Adapter is online
- Power levels are fine
- No errors in EMS
- Attached Brocade switch does not show errors in
porterrshowand ok power levels - SFPs and cables were cleaned
- Cable was replaced
- Issue can be seen on the
loss_of_synccounter of thefcp_portobject:
time interval fcp_port fcp_port instance loss_of_sync------------------------------------ -------- ------------2025-02-06 19:16:43 - 19:21:43+01:00 port.2c 12025-02-06 20:16:43 - 20:21:43+01:00 port.2c 12025-02-06 21:16:43 - 21:21:43+01:00 port.2c 12025-02-06 23:21:43 - 23:26:43+01:00 port.2c 12025-02-07 01:41:43 - 01:46:43+01:00 port.2c 12025-02-07 02:21:43 - 02:26:43+01:00 port.2c 12025-02-07 04:01:43 - 04:06:43+01:00 port.2c 1