Skip to main content
NetApp Knowledge Base

Why CRC errors on the storage controller may follow the placement of a lif?

Views:
1,249
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas
Last Updated:

Applies to

  • Ontap
  • Cut-Through switches

Answer

  • CRC errors seen on ifstat may not be related to the effective communication between that port and the corresponding switch port, if the switch is cut-through
  • Cut-Through switches forward frames before they are completely received, to reduce the latency introduced by storing and forwarding frames
  • A frame containing CRC error will be forwarded to the outbound port by the switch, cause the switch will start forwarding the frames before complete reception
  • When CRC errors are propagated, moving a lif to a different port will have the side effect of redirecting these packets to the new port
  • This gives the impression that CRC errors "follow" the lif to the new port

Additional Information

  • Troubleshooting the origin of CRC errors will be dependent of the specific switch model and vendor being used
  • Please open a case with the switch vendor for further investigation

 

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.