Issue

  • Vscan shows disconnected:

cluster::> vserver vscan connection-status show-not-connected -vserver vs1 -instance
Node: node1
Vserver: vs1
Server: 10.1.1.1
Server Status: disconnected
Server Disconnect Reason: -
Time When Vscan Server Was Disconnected: -
Server Type: primary

  • AVshim log shows below error:

05/15/23-15:06:31.338Z [Pipe: av1.naslab.local] lastStatsSkipTime timeout. Closing pipe...
05/15/23-15:06:48.531Z [Pipe: av1.naslab.local, vs1vs][r] CreateNamedPipe failed with 53. closingQ: [0]

  • Vscan configuration from Ontap and AV server side is correct.
  • Tried restarting AV server but issue still persists.
  • CIFS server is brought down and since then the Vscan shows disconnected.

cluster::> cifs show
Server          Status    Domain/Workgroup Authentication
Vserver     Name            Admin     Name             Style
----------- --------------- --------- ---------------- --------------
vs1         vs1              down      NASLAB           domain

000000x6.0xcxc0e 0xcxxc08 Sun Apr 07 2024 00:31:24 +05:30 [kern_audit:info:2622] 8003e8xxxx0357640:80xx3e800003xx44 :: node01:ssh :: 13x.1cc.1xx.1x:57xx7 :: N01:hxx\user :: vserver cifs stop -vserver V1 :: Pending
000000x6.0xcxcx0f 0xcxcx08 Sun Apr 07 2024 00:31:24 +05:30 [kern_audit:info:2622] 8003e8xxxx7640:8003exxx003xxx44 :: node01:ssh :: 13x.1cc.1xx.1x:57xx7 :: N01:hxx\user :: vserver cifs stop -vserver V1 :: Success

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.