Skip to main content
NetApp Knowledge Base

Is it possible to bind network ports from different nodes to create an ifgroup

Views:
26
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

Applies to

  • ONTAP 9
  • Interface Group (ifgroup)

Answer

  • No, it is not possible to bind physical network ports from different nodes together to create an ifgroup.
  • Ifgroup are designed to aggregate multiple physical ports on the same node to provide redundancy and load balancing.
  • Each ifgroup must be configured on a single node and cannot span across multiple nodes.

Additional Information

Link aggregation groups (LAG) in ONTAP are called ifgroup.

Ethernet Storage Best Practices

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.