DATA lifs become unreachable after lif node failover due to unreachable broadcast-domains
Applies to
- ONTAP 9
- Network
- Vlan
- Switch
Issue
- After failover, LIFs migrated to surviving node and the corresponding vlan tagged port/interface LIFs are unable to communicate and broadcast domain is reported as "unreachable"
::>network port reachability show -instance -port <port_name> Node: <node_name> Reachability Status: no-reachability- EMS messages for broadcast domains not reachable will be seen. Example messages:
[NODE02: vifmgr: vifmgr.reach.noreach:notice]: Network port a0a-40 on node NODE02 cannot reach its expected broadcast domain <broadcast_domain name>. No other broadcast domains appear to be reachable from this port.
[NODE02: vifmgr: vifmgr.reach.noreach:notice]: Network port a0a-41 on node NODE02 cannot reach its expected broadcast domain <broadcast_domain name>. No other broadcast domains appear to be reachable from this port.
[NODE02: vifmgr: vifmgr.reach.noreach:notice]: Network port a0a-43 on node NODE02 cannot reach its expected broadcast domain <broadcast_domain name>. No other broadcast domains appear to be reachable from this port.