Skip to main content
NetApp Knowledge Base

"Broadcast Domain Partitioned" messages for interfaces belonging to the same VLAN

Views:
1,215
Visibility:
Public
Votes:
3
Category:
ontap-9
Specialty:
nas
Last Updated:

Applies to

  • All FAS/AFF systems
  • ONTAP 9.2 and newer

Issue

 

  1. The message below is present in ONTAP logs:
Mon Dec 14 00:38:57 UTC [node01: vifmgr: vifmgr.bcastDomainPartition:error]: Broadcast domain VLAN1190 is partitioned into 2 groups on node node01. The different groups are: {e0a-123}, {e0c-123}. LIFs hosted on the ports in this broadcast domain may be at the risk of seeing connectivity issues.
 
  1. The affected ports are connected to different switches
  2. Switch ports are correctly configured for VLAN trunking
interface Ethernet1/10
switchport mode trunk
switchport trunk allowed vlan 123
 
  1. On switch show vlan brief does not show the VLAN
#show vlan brief
VLAN Name                             Status    Ports
---- -------------------------------- --------- -------------------------------
1    default                          active    Eth1/1
100  management                       active    Eth1/3,Eth1/4
121  data                             active    Eth1/15,Eth1/16
125  voip                             active    Eth1/23,Eth1/24

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.