Windows Host utilities doesn't set recommended values for FCoE HBA adapters
Applies to
- Host Utilities (HU) 7.x
- FCoE Adapter
- Windows Server
Issue
The installation of HU doesn't automatically change the parameters PortDownRetryCount and LinkDownTimeOut to reccommended values for FCoE adapter
C:\Program Files\NetApp\Windows Host Utilities\NetAppQCLI>fcconfig.exe -g
Fibre Channel HBA Configuration Tool - fcconfig 7.2.6666.9999
Copyright (C) 2006 - 2016 NetApp, Inc. All Rights Reserved.
Windows Multipathing (MPIO)..............[INSTALLED]
Host Bus Adapter (HBA) Vendor............[QLogic]
Number of Host Bus Adapters..............[1]
Selected Cluster Failover Mode (CFMODE)..[single_image]
Settings for Adapter 0:
Current LinkDownTimeOut value............[ 0]
Recommended LinkDownTimeOut value........[ 1]
Current PortDownRetryCount value.........[ 0]
Recommended PortDownRetryCount value.....[ 10]