Windows Host utilities doesn't set recommended values for FCoE HBA adapters

Views:
27
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san
Last Updated:

Applies to

  • Host Utilities (HU) 7.x
  • FCoE Adapter
  • Windows Server

Issue

The installation of HU doesn't automatically change the parameters PortDownRetryCount and LinkDownTimeOut to reccommended values for FCoE adapter
 
C:\Program Files\NetApp\Windows Host Utilities\NetAppQCLI>fcconfig.exe -g

Fibre Channel HBA Configuration Tool - fcconfig 7.2.6666.9999
Copyright (C) 2006 - 2016 NetApp, Inc. All Rights Reserved.

Windows Multipathing (MPIO)..............[INSTALLED]
Host Bus Adapter (HBA) Vendor............[QLogic]
Number of Host Bus Adapters..............[1]
Selected Cluster Failover Mode (CFMODE)..[single_image]

Settings for Adapter 0:
Current LinkDownTimeOut value............[ 0]
Recommended LinkDownTimeOut value........[ 1]
Current PortDownRetryCount value.........[ 0]
Recommended PortDownRetryCount value.....[ 10]


 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.