Issue

  • Automated ONTAP upgrade paused while giveback still in progress with error: 

::> cluster image show-update-progress

                                             Estimated         Elapsed
Update Phase         Status                   Duration        Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks    completed                00:10:00        00:01:14
ONTAP updates        paused-on-error          01:32:00        01:56:34

Details:

Node name            Status            Status Description
-------------------- ----------------- --------------------------------------
Node-01        failed            Error: Node "Node-01" is not in
                                       "connected" state after giveback.
                                       Action: Use the "storage failover
                                       show" command to verify that node
                                       "Node-01" is in the "connected"
                                       state, and then use the "cluster
                                       image resume-update" command to
                                       resume the update.
Node-02        completed
6 entries were displayed.

Status: Paused - An error occurred in "ONTAP updates" phase. The update cannot continue until the error has been resolved. Resolve all issues, then use the "cluster image resume-update" command to resume the update.

  • "storage failover show" command output reported “Waiting for cluster applications to come online on the local node. Offline applications: mgmt, vldb, vifmgr, bcomd, crs.” error message for Node-01
  • Observed mgmt and vldb services are offline for Node-01 from "cluster ring show" output.
  • The version command indicates the system is not updated to a higher version.
  •  Node 2 SP/BMC is throwing a mixed version state error.
  • From VLDB Logs:

[kern_vldb:info:6887] rdb::qm:Mon May 22 08:11:03 2023:src/rdb/quorum/quorumimpl.cc:2042 (thr_id:0x80d372700) master_remoteOfflineUpcall: Remote offline upcall remoteId: 1000


kern_vldb:info:6887] rdb::qm:Mon May 22 08:11:03 2023:src/rdb/quorum/qm_states/inq/MasterState.cc:104 (thr_id:0x80d372700) MasterState::commFailure: commFailure occured for site: 1000 at 8145s.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.