Skip to main content
NetApp Knowledge Base

ANDU prechecks fail due to failed task 1618, Upgrade firewall services for deprecation

Views:
139
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

Automated Non-Disruptive Update (ANDU) to ONTAP 9.10 or higher

Issue

  • ANDU to 9.10 or higher precheck fails due to Upgrade firewall services for deprecation

Cluster::*> cluster image show-update-progress 

                                             Estimated         Elapsed
Update Phase         Status                   Duration        Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks    failed                   00:10:00        00:01:05

  • System node upgrade-revert show has the upgrade as aborted on one node and task id 1618 is aborted.  

Cluster::*> upgrade-revert show

  (system node upgrade-revert show)

Node: Cluster-01                                    Status: aborted

Status Message: The upgrade aborted. Contact support personnel for the upgrade repair procedure.


Vers Phase      Status   Upgrade Phase Status Message
---- ---------- -------- ------------------------------------------------------
...
1800 post-apps  aborted  {0}

Cluster::*> upgrade-revert show-task-status -status aborted
  (system node upgrade-revert show-task-status)
Node         Vers Phase     ID  Proc   Status     Description             
------------ ---- --------- --- ------ ---------- -----------------------------
Cluster-01 1600 post-apps 1618 vifmgr aborted   Upgrade firewall services for deprecation

  • Running the task and upgrade manually fails

Cluster::*> upgrade-revert upgrade-task -node Cluster-01 -version 1600 -startup-phase post-apps -process vifmgr -task-id 1618
  (system node upgrade-revert upgrade-task)

Error: command failed: {0}

Cluster::*> upgrade-revert upgrade -node Cluster-01 
  (system node upgrade-revert upgrade)

Notice: Upgrade of row [1600,post-apps,1618,vifmgr] failed. Retrying. Reason:
        {0}. 
Error: Upgrade of row [1600,post-apps,1618,vifmgr] failed. Too many retries. 
       command failed: Upgrade attempt failed. 

  • In the vifmgr logs we see it failed to find the service policy for a node mgmt lif:  

Tue May 23 2023 13:40:32 -05:00 [kern_vifmgr:info:5929] [0x80ab11600] [Net::AbortableHandle::commit] Caught an exception during commit for lif:rdb:4294967295:Cluster-02_mgmt1 (1013): failed to locate service policy for lif

Tue May 23 2023 13:40:32 -05:00 [kern_vifmgr:info:5929] [0x80ab11600] [Net::AbortableHandle::abort] Successfully aborted commit for lif:rdb:4294967295:Cluster-02_mgmt1 (1013)
 

  • Effective Cluster version is the prior ONTAP version.  So a previous ANDU is not complete.   

Cluster::*> version
NetApp Release 9.9.1P5: Sat Nov 20 12:17:23 UTC 2021

  • Nodes have upgraded.  

Cluster::*> node run -node * -c version
2 entries were acted on.

Node: Cluster-01
NetApp Release 9.11.1P5: Sat Dec 10 18:54:17 EST 2022

Node: Cluster-02
NetApp Release 9.11.1P5: Sat Dec 10 18:54:17 EST 2022

  • Node mgmt lifs have a firewall policy.  

Cluster::*> net int show -fields service-policy,firewall-policy -role *mgmt* 
 (network interface show)
vserver   lif                service-policy     firewall-policy 
--------- ------------------ ------------------ --------------- 
Cluster Cluster-01_mgmt1 default-management mgmt            
Cluster Cluster-02_mgmt1 default-management mgmt            
Cluster cluster_mgmt       default-management mgmt            
...
4 entries were displayed.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.