High LUN latency and increased read throughput after an ESXi upgrade
Applies to
- ONTAP 9
- SAN
- ESXi
Issue
- High LUN latency is observed on multiple LUNs across multiple nodes, but no fabric issues are seen (CRCs, etc.).
- The highest delay center under QOS workload statistics is from CPU N-blade (Network column of
qos statistics volume latency show
).
- The highest delay center under QOS workload statistics is from CPU N-blade (Network column of
- In one customer case the latency started post-upgrade of the ESXI host to 7.0.3p, but it can happen at any version of ESXi.
- Coincidentally, there was a throughput increase of read requests from ESXi to ONTAP, maxing out the throughput capacity of the network.