Skip to main content
NetApp Knowledge Base

Storage failover output shows difference in HA nodes when single shelf removed

Views:
106
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
CORE
Last Updated:

Applies to

  • ONTAP 9
  • FAS/AFF systems

Issue

  • In FAS/AFF systems, storage failover show displays different output in HA nodes when remove single disk shelf.
    • When remove cable from SAS port 0a,5b in node-01, it shows:
      ::> storage failover show
                                    Takeover 
      Node           Partner        Possible State Description  
      -------------- -------------- -------- -------------------------------------
      Node-01        Node-02        -        Kernel loaded
      Node-02        Node-01        false    In takeover
    • When remove cable from SAS port 0c,5d in node-02, it shows:
      ::> storage failover show
                                    Takeover          
      Node           Partner        Possible State Description  
      -------------- -------------- -------- -------------------------------------
      Node-01        Node-02        false    Normal giveback not possible:
                                             partner missing file system disks
      Node-02        Node-01        -        Waiting for giveback
  • Systems configuration in normal:
    • Node-01:
      • SYSCONFIG-A:

        slot 0: SAS Host Adapter 0a (Broadcom SAS3616W rev. 2, SAS, <UP>)
            ...
            01.23: NETAPP   X371_S164A960ATE NA54 915.4GB 520B/sect (S5xxxxxxxxxx)
            Shelf 1: DS224-12  Firmware rev. IOM12B A: 0141  IOM12B B: 0141
        slot 5: SAS Host Adapter 5b (Broadcom SAS3616W rev. 2, SAS, <UP>)
            ...
            01.23: NETAPP   X371_S164A960ATE NA54 915.4GB 520B/sect (S5xxxxxxxxxx)
            Shelf 1: DS224-12  Firmware rev. IOM12B A: 0141  IOM12B B: 0141

      •  STORAGE-FAILOVER.XML:

Node    Node-01
Partner Name    Node-02
Local Mailbox Disks    1.1.12.P3, 1.1.13.P3, 1.1.14.P3
Partner Mailbox Disks    1.1.0.P3, 1.1.1.P3, 1.1.2.P3

SYSCONFIG-R

Aggregate aggr0_Node-01 (online, raid_dp, fast zeroed) (block checksums)

  Plex /aggr0_Node-01/plex0 (online, normal, active, pool0)
    RAID group /aggr0_Node-01/plex0/rg0 (normal, block checksums)

      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.01.12P3    0a    1   12  SA:A   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      parity      5b.01.13P3    5b    1   13  SA:B   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      ...
      data        0a.01.22P3    0a    1   22  SA:A   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      data        5b.01.23P3    5b    1   23  SA:B   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      data        0c.11.12P3    0c    11  12  SA:A   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      data        5d.11.13P3    5d    11  13  SA:B   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      ...
      data        0c.11.20P3    0c    11  20  SA:A   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      data        5d.11.21P3    5d    11  21  SA:B   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)

    • Node-02:
      • SYSCONFIG-A:

        slot 0: SAS Host Adapter 0c (Broadcom SAS3616W rev. 2, SAS, <UP>)
            ...
            11.23: NETAPP   X371_S164A960ATE NA54 915.4GB 520B/sect (S5xxxxxxxxxx)
            Shelf 11: DS224-12  Firmware rev. IOM12B A: 0141  IOM12B B: 0141
        slot 5: SAS Host Adapter 5d (Broadcom SAS3616W rev. 2, SAS, <UP>)
            ...
            11.23: NETAPP   X371_S164A960ATE NA54 915.4GB 520B/sect (S5xxxxxxxxxx)
            Shelf 11: DS224-12  Firmware rev. IOM12B A: 0141  IOM12B B: 0141

      • STORAGE-FAILOVER.XML:

        Node    Node-02
        Partner Name    Node-01
        Local Mailbox Disks     1.1.0.P3, 1.1.1.P3, 1.1.2.P3
        Partner Mailbox Disks    1.1.12.P3, 1.1.13.P3, 1.1.14.P3

      • SYSCONFIG-R:

Aggregate aggr0_Node-02 (online, raid_dp, fast zeroed) (block checksums)
  Plex /aggr0_Node-02/plex0 (online, normal, active, pool0)
    RAID group /aggr0_Node-02/plex0/rg0 (normal, block checksums)

      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.01.0P3    0a    1   0   SA:B   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      parity      5b.01.1P3    5b    1   1   SA:A   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      ...
      data        0a.01.10P3    0a    1   10  SA:B   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      data        5b.01.11P3    5b    1   11  SA:A   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      data        0c.11.0P3    0c    11  0   SA:B   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      data        5d.11.1P3    5d    11  1   SA:A   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      ...
      data        0c.11.8P3    0c    11  8   SA:B   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)
      data        5d.11.9P3    5d    11  9   SA:A   0   SSD   N/A 9594/19650048     9602/19666432 (fast zeroed)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.