Storage efficiency not correct applied after conversion to Flexgroup
Applies to
- ONTAP 9
- Flexgroup conversion
Issue
- After converting a Flexvol to a Flexgroup, some of the flexgroup constituents have different storage efficiency settings:
cluster1::*> sis show myvolume*
Vserver Volume State Status Progress Policy
---------- ---------------- --------- ----------- ------------------ ----------
svm0 myvolume Idle - Staggered Policy
Mixed
svm0 myvolume__0001 Idle Idle for 00:00:00 -
Disabled
svm0 myvolume__0002 Idle Idle for 119:14:59 auto
Enabled
3 entries were displayed.
- Trying to enable storage efficiency on all components fail:
::> set d
::*> sis modify myvolume__0001 -policy auto