Storage efficiency not correct applied after conversion to Flexgroup
Applies to
- ONTAP 9
- Flexgroup conversion
Issue
- After converting a Flexvol to a Flexgroup, some of the flexgroup constituents have different storage efficiency settings:
cluster1::*> sis show myvolume*
Vserver Volume State Status Progress Policy
---------- ---------------- --------- ----------- ------------------ ----------
svm0 myvolume Idle - Staggered Policy
Mixed
svm0 myvolume__0001 Idle Idle for 00:00:00 -
Disabled
svm0 myvolume__0002 Idle Idle for 119:14:59 auto
Enabled
3 entries were displayed.
- Trying to enable storage efficiency on all components fail:
::> set d
::*> sis modify myvolume__0001 -policy auto
Error: command failed: Failed to modify efficiency configuration for volume "myvolume__0001" of Vserver "svm0": Operation is not configured.- AUDIT-MLOG-TXT.GZ in ASUP:
filer1:admin :: volume efficiency on -volume volumename__0001 :: Pendingfiler1:admin :: volume efficiency on -volume volumename__0001 :: Successfiler1:admin :: volume efficiency start -volume volumename__0001 :: Pendingfiler1:admin ::volume efficiency start -volume volumename__0001:: Error: Failed to start efficiency on volume "volumename__0001" of Vserver "vservername: Operation is not configured.filer1:admin :: volume efficiency on -volume volumename :: Pendingfiler1:admin ::volume efficiency on -volume volumename:: Error: [Job 37476] Job failed: The efficiency operation was successful but the efficiency state of the FlexGroup has not finished updating. Wait a few minutes, and then checkthat the efficiency state of the volume is "Enabled" using the "volume efficiency show -vserver <vservername> -volume <volumename> -fields state" command. For further assistance, contact technical support.