Applies to

  • AFF C800
  • ONTAP 9

Issue

  • New nodes added to cluster and data migrated via volume move.
  • After migration completed, old nodes removed from cluster and cluster transitioned from switched to switchless.
  • During this process, cables changed from 40G copper to 100G copper on cluster ports e0a and e1a.
  • After this swap, large number of CRC errors and long frames reported on both cluster ports on one node.
  • NodeIfInErrorsWarnAlert reported and system health subsystem show reports degraded cluster.
  • Node reporting CRC errors panics several times:
PANIC: Unknown key type 0 in SK process wafl_exempt18 on release 9.11.1P14 (C)
PANIC: protection fault on VA 0 code 0 cs:rip 0x20:0xffffffff8a950af0 in process NwkThd_00 on release 9.11.1P14 (C)
  • Aggregates on panicking node go to unknown state (causing outage) with discrepancies between VLDB/WAFL in debug vreport show output.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.