Answer

In ONTAP 9.9.1, the override -command will fail with the following error:

::> set diag

::*> vserver config override -command "volume efficiency off -vserver de*ts* -volume sou*"

Error: command failed on vserver "destsvm" volume "source1": This operation is not permitted on a Vserver that is configured as the destination for identity preserve Vserver DR.

Additional Information

  • Previous ONTAP versions do allow the use of wildcards.
ONTAP 9.7:
::*> vserver config override -command "volume efficiency off -vserver des*tsvm* -volume sou*"
Efficiency for volume "source1" of Vserver "destsvm" is disabled.
Efficiency for volume "source2" of Vserver "destsvm" is disabled.
Efficiency for volume "source3" of Vserver "destsvm" is disabled.
3 entries were acted on.
  • Wildcard support is restored via Bug 1498391 - Certain SVM "volume efficiency" configuration override commands fail if used with wildcards
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.