ANDU paused because it failed to migrate data LIFs or cluster-mgmt LIF
Applies to
- ONTAP 9
- Automated Non-Disruptive Upgrade (ANDU)
Issue
- ONTAP ANDU pauses with error message:
Wed May 03 06:16:00 -0700 [cluster-01: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the cluster has been paused due to the following reason: Node "cluster-02": Error: {Failed to migrate data LIFs from node "cluster-01".}, Action: {Migrate all of the data LIFs using the "network interface migrate-all -node cluster-01" command.}.
- LIF configuration error on
VIFMGR.GZ:
Network report: INFORMATIONAL: LIF cluster_mgmt on vserver Vserver-01 is configured with failover policy broadcast-domain-wide but does not have any failover targets on any of the node(s) implied by that policy.
- Broadcast domains only contain a single port