"system controller memory dimm show"command not reflecting the CECC error count
Applies to
- ONTAP 9.5 and later releases
- ONTAP 9.4P6 and later 9.4 releases
- ONTAP 9.3P11 and later 9.3 releases
- ONTAP 9.1P18 and later 9.1 releases
Issue
- "
system controller memory dimm show
" command not reflecting the CECC error count.
::*> system controller memory dimm show -fields cecc-count ,uecc-count ,status
DIMM UECC CECC Alert CPU Slot
Node Name Count Count Method Socket Channel Number Status
------------- ------- ------- ------ ------ ------ ------- ------ --------
Fas8200-01
DIMM-1 0 0 bucket 0 0 0 ok
DIMM-2 0 0 bucket 0 0 1 ok
DIMM-3 0 0 bucket 0 1 0 ok
DIMM-4 0 0 bucket 0 1 1 ok
- "
system node show-memory-errors
" andMEMERR-VERBOSE.XML
log shows increased CECC Count.
::*> system node show-memory-errors
Correctable ECC Memory Errors:
Node:fas8200-01
DIMM CECC Multiple Err
Name Count Same Address
------- ------ ------------
DIMM-1 0 false
DIMM-2 0 false
DIMM-3 1767 false
DIMM-4 0 false
MEMERR-VERBOSE.XML
log
Node Fas8200-01
DIMM Name DIMM-3
Correctable ECC Error Count 1767
Multiple Errors on Same Address false