e0a or e0b exhibit intermittent link flapping in switchless 2-node cluster and recovers
Applies to
- ONTAP 9
- AFF A300, FAS8200
- AFF A200, FAS2650, FAS2620
- AFF A220, AFF C190, FAS2750, FAS2720
Issue
- Cluster ports e0a and e0b on a node experience link flaps or go down at the same time:
Thu Mar 16 12:40:47 -0300 [Node-02: intr: netif.linkDown:info]: Ethernet e0b: Link down, check cable.
Thu Mar 16 12:40:47 -0300 [Node-02: intr: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
Thu Mar 16 12:40:50 -0300 [Node-02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node-02, port e0b.
Thu Mar 16 12:40:50 -0300 [Node-02: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0b on node Node-02 has gone down unexpectedly.
Thu Mar 16 12:40:50 -0300 [Node-02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node-02, port e0a.
Thu Mar 16 12:40:50 -0300 [Node-02: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0a on node Node-02 has gone down unexpectedly.
Thu Mar 16 12:41:40 -0300 [Node-02: intr: netif.linkUp:info]: Ethernet e0b: Link up.
Thu Mar 16 12:41:41 -0300 [Node-02: intr: netif.linkUp:info]: Ethernet e0a: Link up.