What is the impact on the other shelves if one shelf is powered off in a single stack configuration?
Applies to
- ONTAP 9
- Disk shelves in a single stack
Answer
- Disks in a powered-off disk shelf cannot be accessed
- In the case of single-path cabling, all disk shelves downstream from the powered-off disk shelf will be invisible
- In the case of dual-path cabling or more, the path via powered-off disk shelf will be cut off, but as long as the other path is still active, the other disk shelves will fundamentally continue to operate
Note:
- Aggregates using disks from the powered-off and the invisible disk shelf may go offline, which may result in IO outages or failures
- In the case of dual-path cabling or more, there is a risk of delays due to temporary path failover, reduced stack bandwidth, and reduced redundancy
Additional Information
additionalInformation_text