Skip to main content
NetApp Knowledge Base

What is the impact on the other shelves if one shelf is powered off in a single stack configuration?

Views:
167
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • Disk shelves in a single stack

Answer

  • Disks in a powered-off disk shelf cannot be accessed
  • In the case of single-path cabling, all disk shelves downstream from the powered-off disk shelf will be invisible
  • In the case of dual-path cabling or more, the path via powered-off disk shelf will be cut off, but as long as the other path is still active, the other disk shelves will fundamentally continue to operate

Note: 

  • Aggregates using disks from the powered-off and the invisible disk shelf may go offline,  which may result in IO outages or failures
  • In the case of dual-path cabling or more, there is a risk of delays due to temporary path failover, reduced stack bandwidth, and reduced redundancy

Additional Information

additionalInformation_text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.