VMware ESXi outage during MCC switchover with Qlogic 2690
Applies to
- ONTAP 9.9
- MetroCluster
- ESXi 7.0 u3
- Host HBA Qlogic 2690
Issue
- During planned maintenance which involves an MCC switchover / switchback an ESXi Host had multiple IO failures on all paths
- After Metrocluster switchover ,
fcp initiator show
is missing several initiators from hosts igroup show -instance shows
Host initiators not logged in- Host uses Qlogic 2690