ANDU paused : local node missing partner disks due to miscabling
Applies to
- FAS
- ONTAP 9
- ANDU (Automatic non disruptive upgrade)
Issue
- Error message in
Storage Failover Showduring the validation step of ANDU (automatic non-disruptive upgrade) :
::> storage failover showTakeoverNode Partner Possible State Description------------------------------------------------------------------------Node-01 Node-02 false System ID changed on partner (Old: 025XXXXXX, New: 538XXXXXX), Normal giveback not possible: partner missing filesystem disksNode-02 Node-01 -- Waiting for giveback
EMS-LOG-FILE:
node1 ALERT cf.disk.invent.mismatchalt: Status of some of the disks has changed or the node (node1) is missing 4 disks (detailed logs have been throttled).
node1 ERROR cf.disk.inventory.mismatch: Status of the disk ?.? (5000CCA0:1D0DDEA4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node1) is missing the disk.
node1 ERROR cf.disk.inventory.mismatch: Status of the disk ?.? (5000CCA0:724C29B8:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node1) is missing the disk.
node1 ERROR cf.disk.inventory.mismatch: Status of the disk ?.? (5000CCA0:1D0F63E8:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node1) is missing the disk.
node2 ERROR cf.disk.inventory.mismatch: Status of the disk ?.? (5000CCA0:1D06B56C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node2) is missing the disk.
SYSCONFIG -A:
System Storage Configuration: Single-Path HA for both nodes
- Cabling: The shelf is not detected via one of the nodes.