Issue

  • SystemStorage Configuration shows Mixed-path from sysconfig -a output.
  • system health alert show reports the same

::> system health alert show

Node: node01
Resource: Shelf 4.11
Severity: Major
Indication Time: Tue Jan 30 21:00:54 2024
Suppress: false
Acknowledge: false
Probable Cause: Controller JC8FAS02-03 has only a single-path configuration to disk shelf 4.11. This might occur when the controller does not have dual-path
configuration to stack 4, a SAS HBA port on the controller connected to the disk shelf is disabled, or shelf-to-shelf cabling is incorrect.

  • EMS logs:

Fri Apr 07 15:26:37 [node01:dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
Fri Apr 07 15:26:37 [node01:dsa_disc: shelf.config.mixedha:notice]: System is using a mixture of single path, multi-path or quad-path HA storage configurations.
Fri Apr 07 15:26:29 [node02: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
Fri Apr 07 15:26:29 [node02: dsa_disc: shelf.config.mixedha:notice]: System is using a mixture of single path, multi-path or quad-path HA storage configurations.

  • No fault LEDs are light on the IOM module.
  • Check the shelf path by running "system node run -node {nodename|local} -command sasadmin expander_map" command from the console, or examining "SAS-EXPANDER-MAP" in ASUP.

Node01: port 0c connects with shelf 10/11/12 by IOM A(shelf 13/14 is missing), port 2d connects with shelf 14/13/12/11/10 by IOM B. 

Expanders on channel 0c: 
Level    1: WWN 500a098008657ca9, ID 10, Serial Number ' SHJSG2234000411', Product 'DS22412IOM12A  ', Rev '0300', Slot A
Level    2: WWN 500a098008657cb9, ID 11, Serial Number ' SHJSG2234000394', Product 'DS22412IOM12A  ', Rev '0300', Slot A
Level    3: WWN 500a09800865817d, ID 12, Serial Number ' SHJSG2234000050', Product 'DS22412IOM12A  ', Rev '0300', Slot A

Expanders on channel 2d: 
Level    1: WWN 500a098008658569, ID 14, Serial Number ' SHJSG2234000373', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level    2: WWN 500a098008658415, ID 13, Serial Number ' SHJSG2234000381', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level    3: WWN 500a098008657ea5, ID 12, Serial Number ' SHJSG2234000050', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level    4: WWN 500a098008657b35, ID 11, Serial Number ' SHJSG2234000394', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level    5: WWN 500a098008657c95, ID 10, Serial Number ' SHJSG2234000411', Product 'DS22412IOM12A  ', Rev '0300', Slot B

Node02: port 0c connects with shelf 10/11/12/13/14 by IOM B, port 2d connects with shelf 14/13 by IOM A(shelf 12/11/10 is missing). 

Expanders on channel 0c: 
Level    1: WWN 500a098008657c95, ID 10, Serial Number ' SHJSG2234000411', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level    2: WWN 500a098008657b35, ID 11, Serial Number ' SHJSG2234000394', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level    3: WWN 500a098008657ea5, ID 12, Serial Number ' SHJSG2234000050', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level    4: WWN 500a098008658415, ID 13, Serial Number ' SHJSG2234000381', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level    5: WWN 500a098008658569, ID 14, Serial Number ' SHJSG2234000373', Product 'DS22412IOM12A  ', Rev '0300', Slot B

Expanders on channel 2d: 
Level    1: WWN 500a098008658585, ID 14, Serial Number ' SHJSG2234000373', Product 'DS22412IOM12A  ', Rev '0300', Slot A
Level    2: WWN 500a098008658511, ID 13, Serial Number ' SHJSG2234000381', Product 'DS22412IOM12A  ', Rev '0300', Slot A

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.