Skip to main content
NetApp Knowledge Base

PHY X is reporting an unknown link rate for all drawers managed by Module B

Views:
236
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

Applies to

  • DS460C shelves
  • IOM12B

Issue

  • PHY X is reporting an unknown link rate alerts generated for all drawers that managed by IOM12B B module.

EMS:
[?]  Thu Jul 25 20:00:00 [node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[?]  Thu Jul 25 20:00:32 [node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "1", PHY "0" is reporting an unknown link rate.
[?]  Thu Jul 25 20:00:32 [node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "2", PHY "0" is reporting an unknown link rate.
[?]  Thu Jul 25 20:00:32 [node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "3", PHY "0" is reporting an unknown link rate.
[?]  Thu Jul 25 20:00:32 [node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "4", PHY "0" is reporting an unknown link rate.
[?]  Thu Jul 25 20:00:32 [node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "5", PHY "0" is reporting an unknown link rate.

[?]  Thu Jul 25 20:00:00 [node-02: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[?]  Thu Jul 25 20:00:07 [node-02: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "1", PHY "0" is reporting an unknown link rate.
[?]  Thu Jul 25 20:00:07 [node-02: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "2", PHY "0" is reporting an unknown link rate.
[?]  Thu Jul 25 20:00:07 [node-02: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "3", PHY "0" is reporting an unknown link rate.
[?]  Thu Jul 25 20:00:07 [node-02: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "4", PHY "0" is reporting an unknown link rate.
[?]  Thu Jul 25 20:00:07 [node-02: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "5", PHY "0" is reporting an unknown link rate.

STORAGE FAULT SHOW -V
Enclosure Status: information
Channel: 0a
Shelf: 0
Shelf Type: DS460-12
Product Serial Number: xxxxxxxxxxxxx
Module Type: IOM12B

Enclosure:
Element Status         Status Bytes  Status Descriptions
1: OK                01,00,02,00   FAIL

Drawers Control Module:
Element Status                      Status Bytes  Status Descriptions
1 [IOM12B A]    : OK                01,00,01,01   REPORT, TYPE BIT0
2 [IOM12B A]    : OK                01,00,01,01   REPORT, TYPE BIT0
3 [IOM12B A]    : OK                01,00,01,01   REPORT, TYPE BIT0
4 [IOM12B A]    : OK                01,00,01,01   REPORT, TYPE BIT0
5 [IOM12B A]    : OK                01,00,01,01   REPORT, TYPE BIT0
6 [IOM12B B]    : CRITICAL          02,40,00,00   FAIL
7 [IOM12B B]    : CRITICAL          02,40,00,00   FAIL
8 [IOM12B B]    : CRITICAL          02,40,00,00   FAIL
9 [IOM12B B]    : CRITICAL          02,40,00,00   FAIL
10 [IOM12B B]    : CRITICAL          02,40,00,00   FAIL

SYSCONFIG-A
Shelf 0: DS460-12  Firmware rev. IOM12B A: 0100  IOM12B B: 0100

  • From the SYSCONFIG-A, there are no missing disks.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.