PHY X is reporting an unknown link rate for all drawers managed by Module B
Applies to
- DS460C shelves
- IOM12B
Issue
- PHY X is reporting an unknown link rate alerts generated for all drawers that managed by IOM12B B module.
EMS:
[?] Thu Jul 25 20:00:00 [node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[?] Thu Jul 25 20:00:32 [node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "1", PHY "0" is reporting an unknown link rate.
[?] Thu Jul 25 20:00:32 [node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "2", PHY "0" is reporting an unknown link rate.
[?] Thu Jul 25 20:00:32 [node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "3", PHY "0" is reporting an unknown link rate.
[?] Thu Jul 25 20:00:32 [node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "4", PHY "0" is reporting an unknown link rate.
[?] Thu Jul 25 20:00:32 [node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "5", PHY "0" is reporting an unknown link rate.
[?] Thu Jul 25 20:00:00 [node-02: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[?] Thu Jul 25 20:00:07 [node-02: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "1", PHY "0" is reporting an unknown link rate.
[?] Thu Jul 25 20:00:07 [node-02: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "2", PHY "0" is reporting an unknown link rate.
[?] Thu Jul 25 20:00:07 [node-02: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "3", PHY "0" is reporting an unknown link rate.
[?] Thu Jul 25 20:00:07 [node-02: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "4", PHY "0" is reporting an unknown link rate.
[?] Thu Jul 25 20:00:07 [node-02: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "0", module "B", drawer "5", PHY "0" is reporting an unknown link rate.
STORAGE FAULT SHOW -V
Enclosure Status: information
Channel: 0a
Shelf: 0
Shelf Type: DS460-12
Product Serial Number: xxxxxxxxxxxxx
Module Type: IOM12B
Enclosure:
Element Status Status Bytes Status Descriptions
1: OK 01,00,02,00 FAIL
Drawers Control Module:
Element Status Status Bytes Status Descriptions
1 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
2 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
3 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
4 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
5 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
6 [IOM12B B] : CRITICAL 02,40,00,00 FAIL
7 [IOM12B B] : CRITICAL 02,40,00,00 FAIL
8 [IOM12B B] : CRITICAL 02,40,00,00 FAIL
9 [IOM12B B] : CRITICAL 02,40,00,00 FAIL
10 [IOM12B B] : CRITICAL 02,40,00,00 FAIL
SYSCONFIG-A
Shelf 0: DS460-12 Firmware rev. IOM12B A: 0100 IOM12B B: 0100
- From the SYSCONFIG-A, there are no missing disks.