ONTAP Upgrade Paused Due to hardware failures on both clusters leading to "Failed" or "Prefailed" disks
Applies to
- AFF A250
- ONTAP 9.15.1P10, 9.16.1P11
- 4 Node MetroCluster IP
Issue
During an ONTAP upgrade on Metrocluster IP on Cluster Cluster02, multiple disks failed, resulting in node Cluster02-01 entering a down state and pausing the automated upgrade.
Console and log outputs indicated:
- Disk errors on shelf 0, slot 12 and slot 13 (SSD-NVM, 1.75TB)
- Node unable to boot due to a failed PCIe card in slot 1
- Log output example:
card in slot 1 is failed log(7) msg(mt(1)), Hdr[1]<0x230000ff>(RqBusNum(35),RqDvNum(0),RqFncNum(0),Tag(0),LstDwBe(15),1stDwBe(15)), Hdr[2]<0x00000001>((0x1)), Hdr[3]<0x0a0e3000>((0xa0e3000)); Addr(0x10a0e3000),Dv[101b](35,0,1) in slot 1: Status(SigSysErr), DevStatus(Corr,Fatal), CorrErr(RNRov,RpTim), UCorrErr(MfTLP), FirstUCorrErr(MfTLP), TLPType(CmplRsp),Hdr[0]<0x4a008004>(HdrLen(4),AddrType(0),Attr(0),Td,Tc(0),Type(10),Fmt(2)), Hdr[1]<0x00000010>(CmplBusNum(0),CmplDvNum(0),CmplFncNum(0),CmplSts(0),ByteCnt(1)Rec(1) @ 0x804, flag(0x0) len(100) tstamp(0x69d17cf8)
disk show -brokenoutput example:::> disk show -container-type broken Usable Disk Container Container Disk Size Shelf Bay Type Type Name Owner ---------------- ---------- ----- --- ------- ----------- --------- -------- 2.0.12 1.75TB 0 12 SSD-NVM broken - Cluster02-01 2.0.13 1.75TB 0 13 SSD-NVM broken - Cluster02-01 2.0.16 1.75TB 0 16 SSD-NVM broken - Cluster02-01 3 entries were displayed.- Node status: Cluster02-01 offline