Skip to main content
NetApp Knowledge Base

Node not responding with DualControllerNonHa_Alert notifications

Views:
113
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS8200
  • ONTAP 9.11.1P2

Issue

  • Node not responding
  • EMS alerts for multiple shelves:

[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f4:f9 raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f5:19 raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f7:2c raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:ff:c0 raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:38:8c:6c raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:38:8f:50 raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:0b:32:aa:47 raised by monitor system-connect

 

[node_name-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: DualControllerNonHa_Alert[50:0a:09:80:08:37:f4:f9].

  • Health alerts reported:

Monitor           system-connect
Alert ID          DualControllerNonHa_Alert
Subsystem         SAS-connect_Cluster
Probable Cause    Configuration_error
Description
   Storage shelf 22 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
   Storage shelf 21 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
   Storage shelf 23 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
   Storage shelf 13 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
   Storage shelf 11 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
   Storage shelf 20 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
   Storage shelf 10 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.

  • Alerts cleared after node reboot:

[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f4:f9 cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f5:19 cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f7:2c cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:ff:c0 cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:38:8c:6c cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:38:8f:50 cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:0b:32:aa:47 cleared by monitor system-connect

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.