NoPathToNSMA_Alert seen from node and NoPathToNSMB_Alert seen from partner node
Applies to
- NS224 shelf
- ONTAP 9
Issue
- In the
sysconfig -alog, System Storage Configuration: is displayed asSingle-Path HA. - When performing
Takeover/Giveback, the following error occurs.
Port e4a on controller Node2 is connected to port e0b on module A of shelf 1.0.
Corrective Actions:
1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
2. Connect e4a to e0a on either module of shelf 1.0.
- Health alert for both
NSMAandNSMBmodules.
Node:node-1
Monitor : node-connect
Alert ID :NoPathToNSMA_Alert
Alerting Resource :*****
Subsystem : SAS-connect
Indication Time : Fri Feb 28 15:03:15 2025
Perceived Severity : Major
Probable Cause : Cable_tamper
Corrective Actions :
1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
2. Connect controller Node1 to module A and module B of shelf 1.0.
- Or Although the HA Pair attached to the NS224 shelf shows as Multi-Path from the
sysconfig -anodeshell command output, the following alerts are seen:
Node 01 shows
NoPathToNSMA_AlertNode 02 shows
NoPathToNSMB_Alert