NoPathToNSMA_Alert or NSMB with correct cabling
Applies to
- NS224 shelf
- ONTAP 9
Issue
- Daily AutoSupports triggered for disk redundancy failure:
HA Group Notification (DISK REDUNDANCY FAILED) ERROR- After reboot for any reason (including ONTAP upgrade) health alert reported post-reboot:
HA Group Notification (Health Monitor process nchm: NoPathToNSMA_Alert[xxxxxxxxxxxxxxxxxxxx]) ALERT- Node may also report
NoPathToNSMB_Alertto one or more shelves. - Cabling appears correct, but mapping out cabling per How to map out NS224 shelf cabling in ONTAP 9 shows some connections are down.
- Note: In below example, port 1 is OK (reports attached port and manufacturer) but port 2 is down/missing the normal information.
External Ethernet Connector information by element: [1] MAC address: d0:39:ea:xx:xx:xx Attached MAC address: d0:39:ea:xx:xx:xx Attached port: e1a Attached chassis: d0:39:ea:xx:xx:xx Attached manufacturer: cluster-01 Cable serial number: APF23469670123 Cable vendor name: Amphenol Cable id: QSFP28 Cable end: 0 Cable technology: passive copper Cable length: 2m [2] MAC address: d0:39:ea:xx:xx:xx Attached MAC address: <N/A> Attached port: <N/A> Attached chassis: <N/A> Attached manufacturer: <N/A> Cable serial number: APF23469670124 Cable vendor name: Amphenol Cable id: QSFP28 Cable end: 0 Cable technology: passive copper Cable length: 2m