NSM100 DIMM is unknown and disks are not seen behind module
Applies to
Issue
- There is a fault LED on the NS224 shelf
- In
storage show fault -v
output, we can see the following error for DIMM on the NSM100
DIMM:
Element Status Status Bytes Status Descriptions
1 [NSM100 A] : OK 01,00,00,00
2 [NSM100 A] : OK 01,00,00,00
3 [NSM100 A] : OK 01,00,00,00
4 [NSM100 A] : UNKNOWN 06,00,00,00
5 [NSM100 B] : OK 01,00,00,00
6 [NSM100 B] : OK 01,00,00,00
7 [NSM100 B] : OK 01,00,00,00
8 [NSM100 B] : OK 01,00,00,00
- Although both storage ports to this module are UP, the disks are not seen behind either path/node to this module:
System Storage Configuration: Mixed-Path HA
slot 0: Dual 40G/100G Ethernet Controller CX5
e0c MAC Address: a0:11:22:33:aa:44 (auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00573
QSFP Serial Number: APF123456789
e0d MAC Address: a0:11:22:33:aa:44 (auto-100g_cr4-fd-up)
e5b MAC Address: b0:aa:a1:b2:b3:44 (auto-100g_cr4-fd-up)
QSFP Vendor: Molex
QSFP Part Number: 112-00574
QSFP Serial Number: 93A123456789
Device Type: CX5 PSID(NAP0000001002)
Firmware Version: 16.26.4012
Part Number: MCX516A-CCAT_C21
Hardware Revision: B2
Serial Number: MT12345657890 <<<< Missing disks behind adapters
slot 0: Virtual iSCSI Host Adapter 0m
- Both connections misisng disks are to this module, which can be see in the
device-discovery
ASUP output:
NetApp NS224.NSM100.SH00.A (v.0203)
NetApp NS224.NSM100.SH00.A (v.0203)