Incorrectly configured storage ports result in unsupported and SNMP alerts
Applies to
- FAS/AFF
- ONTAP
- NS224
- Storage Switch
- Data Switch
Issue
SwitchCommunityString_AlertandUnsupportedSwitch_Alertis present on the health alert table
::> system health alert show Node: Cluster1- Monitor: ethernet-switch Alert ID: SwitchCommunityString_Alert Node: Node-1 Monitor: ethernet-switch Alert ID: UnsupportedSwitch_Alert- The affected switch is not directly connected to any NSMs and is used for network traffic and is connected to a storage port
Cluster1::> storage shelf show -fields initiator
shelf initiator
----- ---------
1.0 e3b , e5a
Cluster1::> storage port show
Speed VLAN
Node Port Type Mode (Gb/s) State Status ID
------------------ ---- ----- ------- ------ -------- --------- ----
Cluster1-01
e3a ENET storage 100 enabled online 30 <--- Needs to be changed to a Network port
e3b ENET storage 100 enabled online 30
e5a ENET storage 100 enabled online 30
e5b ENET storage 100 enabled online 30 <--- Needs to be changed to a Network port
Cluster1-02
e3a ENET storage 100 enabled online 30 <--- Needs to be changed to a Network port
e3b ENET storage 100 enabled online 30
e5a ENET storage 100 enabled online 30
e5b ENET storage 100 enabled online 30 <--- Needs to be changed to a Network port