Health Monitor process nchm: NoPathToNSMA_Alert with multiple link flaps
Applies to
- FAS500f
- NS224 NVMe shelf with NSM100 (NVMe Shelf Module 100 Gb)
Issue
- ASUP alerts (one or the other or both):
HA Group Notification (Health Monitor process nchm: NoPathToNSMA_Alert[xxxxxxxxxxxxxxxxxxx]) ALERT
HA Group Notification (Health Monitor process nchm: NoPathToNSMB_Alert[xxxxxxxxxxxxxxxxxxx]) ALERT
- Multiple raised/cleared health monitor alerts:
system health alert show
Node cluster1-01
Monitor node-connect
Alert ID NoPathToNSMA_Alert
Subsystem SAS-connect
Indication Time Mon Sep 20 19:05:40 2021
Perceived Severity Major
Probable Cause Cable_tamper
Description Controller cluster1-01 is connected only to module B of shelf 1.1 through port e1b.
- Multiple up to down port flaps:
Fri Oct 01 19:54:11 -0400 [dhmfas4-01: kernel: netif.linkDown:info]: Ethernet e1b: Link down, check cable.
Fri Oct 01 19:54:14 -0400 [dhmfas4-01: kernel: netif.linkUp:info]: Ethernet e1b: Link up.
Fri Oct 01 19:56:20 -0400 [dhmfas4-01: kernel: netif.linkDown:info]: Ethernet e1b: Link down, check cable.
Fri Oct 01 19:56:24 -0400 [dhmfas4-01: kernel: netif.linkUp:info]: Ethernet e1b: Link up.