Giveback is canceled with the message "Run the storage failover show-giveback command to check giveback status"
Applies to
- FAS and AFF Platform
- ONTAP 9
Issue
- Proceed giveback from node-1 to node-2, an event occurs and cannot giveback.
Example:
Cluster::> storage failover giveback -ofnode node-2
Info: Run the storage failover show-giveback command to check giveback status.
Cluster::> storage a failover show
Takeover
Node Partner Possible State Description
-------------- -------------- -------- -------------------------------------
node-1 node-2 false Previous giveback failed in module:
autosupport. Auto giveback will be initiated in 283 seconds
node-2 node-1 - Waiting for giveback
2 entries were displayed.
- The following message is output in the "
event log show
" When an event occurred.
Example:
2/8/2021 17:31:29 node-1 ALERT cf.rsrc.givebackVeto: Failover monitor: autosupport: giveback canceled due to active state.
- Checking the "
autosupport-history.xml
" status of the target time in the item of "Last Error
" column from AutoSupport, confirm the following message.
Example:
"AutoSupport collection is delayed due to DBLADE delay request due to takeover/giveback. AutoSupport collection will be retried."