Failure to assign NVMe disk drives having the wrong sector size
Applies to
- ONTAP 9
- NVMe disk drives formatted with 4096B/sect
Issue
- Newly received NVMe disk drives fail to get assigned
::> storage disk assign 1.0.4 -owner node-01
Error: Failed to assign disks. Reason: Storage disk assign failed: Non Redundancy errors were detected on disk 1.0.4. Use 'storage errors show' for detailed information.
- Disks show to have unsupported Block/Sector format
::> node run -node node-01 -command sysconfig -a
...
--> GOOD 3 : NETAPP X4024S173A1T9NTE NA50 1831.1GB 4160B/sect (S7J8NN0Y301111)
--> FAIL 4 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4096B/sect (S60RNE0N503333)