FAS9500 or AFF-A900 sysconfig: Card in slot X (1-15xx-xx1B-0) is not supported when reboot
Applies to
- ONTAP 9
- FAS9500
- AFF-A900
- X91153A
Issue
- When the CX6 network ports located in the same slot of two nodes are interconnected, the following error is reported upon node reboot:
sysconfig: Card in slot 5 (1-15B3-101B-0) is not supported.
Aug 22 12:17:03 [Node-01:cmds.sysconf.logErr:notice]: sysconfig: Card in slot 5 (1-15B3-101B-0) is not supported.
.
Aug 22 12:17:03 [Node-01:callhome.sys.config.crit:error]: Call home for SYSTEM CONFIGURATION ERROR
Aug 22 12:17:03 [Node-01:kern.syslog.msg:notice]: domain xing mode: off, domain xing interrupt: false
Architectural Performance Monitoring Information for CPU type 6, Model 106:
Node01> sysconfig -ac
sysconfig: Card in slot 5 (1-15B3-101B-0) is not supported.
sysconfig: slot 7 OK: X91153A: 2p 40G/100G RoCE QSFP28
- The X91153A network port may do not link up or disappeared from
SYSCONFIG-Aandnetwork port show
Node: Node-01
e4a Cluster Cluster up 9000 auto/100000 healthy
e4b Cluster Cluster up 9000 auto/100000 healthy
Node: Node-02
e4a Cluster Cluster up 9000 auto/100000 healthy
e4b Cluster Cluster up 9000 auto/100000 healthy
e5a Default Default-3 down 1500 auto/- -
e5b Default Default-3 down 1500 auto/- -
e7a Default Default-4 down 1500 auto/- -
e7b Default Default-4 down 1500 auto/- -
- Upgrade ONTAP to 9.15.1 don't resolve the issue:
- halt the node may stuck for a while:
Warning: Are you sure you want to halt node "Node-01"?
{y|n}: y
Warning: Are you sure you want to halt node "Node-02"?
{y|n}: y
2 entries were acted on.
login: Terminated
.
Kernel thread "tmp_monitor" (pid 0) exited prematurely.
Uptime: 3h20m35s
FM halt: Time 11803926 ms, 392616588596757 cycles
- When port in same slot connected to each other, the error disappears and port link status recovers.