Skip to main content
NetApp Knowledge Base

FAS9500 or AFF-A900 sysconfig: Card in slot X (1-15xx-xx1B-0) is not supported when reboot

Views:
317
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • FAS9500
  • AFF-A900
  • X91153A

Issue

  • When the CX6 network ports located in the same slot of two nodes are interconnected, the following error is reported upon node reboot:

sysconfig: Card in slot 5 (1-15B3-101B-0) is not supported.
Aug 22 12:17:03 [Node-01:cmds.sysconf.logErr:notice]: sysconfig: Card in slot 5 (1-15B3-101B-0) is not supported.
.
Aug 22 12:17:03 [Node-01:callhome.sys.config.crit:error]: Call home for SYSTEM CONFIGURATION ERROR
Aug 22 12:17:03 [Node-01:kern.syslog.msg:notice]: domain xing mode: off, domain xing interrupt: false
Architectural Performance Monitoring Information for CPU type 6, Model 106:

Node01> sysconfig -ac

sysconfig: Card in slot 5 (1-15B3-101B-0) is not supported.
sysconfig: slot 7 OK: X91153A: 2p 40G/100G RoCE QSFP28

  •  The X91153A network port may do not link up or disappeared from SYSCONFIG-A and network port show

Node: Node-01

e4a       Cluster      Cluster          up   9000  auto/100000 healthy
e4b       Cluster      Cluster          up   9000  auto/100000 healthy

Node: Node-02

e4a       Cluster      Cluster          up   9000  auto/100000 healthy
e4b       Cluster      Cluster          up   9000  auto/100000 healthy
e5a       Default      Default-3        down 1500  auto/-     -
e5b       Default      Default-3        down 1500  auto/-     -
e7a       Default      Default-4        down 1500  auto/-     -
e7b       Default      Default-4        down 1500  auto/-     -

  • Upgrade ONTAP to 9.15.1 don't resolve the issue:
  • halt the node may stuck for a while:

Warning: Are you sure you want to halt node "Node-01"?

{y|n}: y

Warning: Are you sure you want to halt node "Node-02"?
{y|n}: y
2 entries were acted on.

login: Terminated
.
Kernel thread "tmp_monitor" (pid 0) exited prematurely.
Uptime: 3h20m35s
FM halt: Time 11803926 ms, 392616588596757 cycles

  • When port in same slot connected to each other, the error disappears and port link status recovers.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.