EMS reports "cmds.sysconf.logErr:notice" after upgrading ONTAP to 9.3
Applies to
ONTAP 9.3
Issue
- EMS reports "cmds.sysconf.logErr:notice" after upgrading ONTAP to 9.3P21.
Example:
[Node01: sysconfig_periodic_checker: cmds.sysconf.logErr:notice]: sysconfig: slot 1: Number of the Broadcom LPE16004; Quad-Port 16Gb card (PN X1145A) exceeds supported maximum (1). sysconfig: slot 2: Number of the Broadcom LPE16004; Quad-Port 16Gb card (PN X1145A) exceeds supported maximum (1). .
- X1133A-R6 HBA cards are installed, but ONTAP instead displays a message about an X1145A HBA card in the output of the
sysconfig -ac
command.
Before:
sysconfig: slot 1 OK: X1133A: Broadcom LPe16004 rev. A0
sysconfig: slot 2 OK: X1133A: Broadcom LPe16004 rev. A0
After upgrading ONTAP to 9.3:
sysconfig: slot 1: Number of the Broadcom LPE16004; Quad-Port 16Gb card (PN X1145A) exceeds supported maximum (1).