Skip to main content
NetApp Knowledge Base

EMERGENCY Controller failover of node_name is not possible. Unsynchronized log

Views:
6,777
Visibility:
Public
Votes:
1
Category:
aff-series
Specialty:
HW
Last Updated:

Applies to

  • AFF A700
  • FAS9000
  • ONTAP 9

Issue

  • EMS Emergency message:
[monitor: monitor.globalStatus.critical:EMERGENCY]: Controller failover of node_name_2 is not possible: unsynchronized log.
[cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of NodeA disabled (unsynchronized log).
[cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of NodeB by NodeA disabled (unsynchronized log).
[ib_cm_wq: nvmm.mirror.aborting:debug]: mirror of sysid 1, partner_type HA Partner and mirror state MIRROR_ONLINE is aborted because of reason Abort Pending.
  • This is a transient issue not persistent. 
  • Storage failover is enabled.
  • System Health is fine and no Health Alerts present.
  • Flapping interconnect link issue in both nodes:
gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is down.
gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is up.
gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is down.
gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is up.
...
 
gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is down.
gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is up.
gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is down.
gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is up.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.