Disk auto replacement starts at the partner node after assigning internal spare disk
Applies to
- ONTAP 9
- FAS2820
- FAS2720
- FAS2750
- Data aggregates using shared disks from the internal and the external shelf
raid.lm.disk.copyback.enableset to on
Issue
- After replacing faulty disk at node02, assign the partition disk to node02 spare pool, but P1 partition auto-assign to node01 and start to replace the 02.7P1 data disk.
Thu Aug 07 10:57:30 +0900 [node02: dmgr_thread: raid.disk.inserted:info]: Disk 0b.00.2 Shelf 0 Bay 2 [NETAPP X336_SCBPE04TA07 NA01] S/N [xxxxxxx] UID [5000C500:F9093037:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the system
Thu Aug 07 11:09:42 +0900 [node02: sanown_io: diskown_changingOwner_1:notice]: params: {'diskname': '0b.00.2P1','oldownername': 'unowned', 'newownername': 'node02'}
Thu Aug 07 11:10:02 +0900 [node02: sanown_io: diskown_changingOwner_1:notice]: params: {'diskname': '0b.00.2P2','oldownername': 'unowned', 'newownername': 'node02' }
Thu Aug 07 11:10:52 +0900 [node02 sanown_io: diskown_changingOwner_1:notice]: params: {'diskname': '0b.00.2P1','oldownername': 'node02', 'newownername': 'node01', }
Thu Aug 07 11:11:03 +0900 [node01: config_thread: raid.rg.diskcopy.start:notice]: /Cluster01_01_NL_SAS_1/plex0/rg0: starting disk copy from 0b.02.7P1 (S/N [xxxxxxx]) to 0b.00.2P1 (S/N [xxxxxxx]). Reason: Disk replace was started..- No disk replace event occur between 00.2 and 02.7 ever.