Skip to main content
NetApp Knowledge Base

Detection of BATTERY charge FET off ALERT in the fixed version of Bug1063994

Views:
261
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS2650
  • ONTAP 9
  • Service Processor (SP)

Issue

  • The system triggers a (BATTERY (charge FET off)) ALERT.

HA Group Notification from node-1 (BATTERY (charge FET off)) ALERT

EMS log:

Thu Aug 24 04:41:21 JST [node-1: env_mgr: nvmem.battery.FET.off:debug]: The NVMEM battery charge FET is off. To prevent data loss, the system will shut down in 24 hours.
Thu Aug 24 04:41:32 JST [node-1: env_mgr: nvmem.battery.tempLow:debug]: The NVMEM battery is too cold (-17 C). To prevent data loss, the system will shut down in 24 hours.
Thu Aug 24 04:41:54 JST [node-1: env_mgr: nvmem.battery.temp.normal:debug]: The NVMEM battery temperature is normal.
Thu Aug 24 04:41:54 JST [node-1: env_mgr: nvmem.battery.packValid:debug]: A valid NVMEM battery pack is present.
Thu Aug 24 04:42:06 JST [node-1: env_mgr: nvmem.battery.FET.normal:debug]: The NVMEM battery charge FET is on.
Thu Aug 24 04:42:24 JST [node-1: env_mgr: callhome.battery.warning:debug]: Call home for BATTERY (charge FET off) WARNING.

  • No learning cycle was performed during the corresponding time period.

LrnCycleStartDate :
23-07-21-12:00
LrnCycleStartFCC  : 0x0560
LrnCycleEndFCC    : 0x0556
LrnCycleEndDate   :
23-07-21-23:3

  • The service processor (SP) version is SP5.3 which is Bug#1063994 fixed version.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.