Issue

  • The shelf front warning LED is blinking.
  • EMS Log shows  Cooling Fan and Temperature Sensor Not Installed Warning.

[ses.status.fanWarning:notice]: DS212-12 (S/N *****) shelf 1 on channel 0b cooling fan warning for Cooling element 1: not installed. This module is on the rear of the shelf on the lower left power supply.
[callhome.shelf.fan.warn:error]: Call home for SHELF COOLING UNIT FAILED
[ses.status.temperatureWarning:alert]: DS212-12 (S/N ****) shelf 1 on channel 0b temperature warning for Temperature sensor 6: not installed. Current temperature:  C ( F). This module is on the rear of the shelf on the lower left power supply.

  • ENVIRONMENT log shows multiple sensors are Unavailable.

Channel: 0a
    Shelf: 1
    SES device path: local access: 0b.01.99
    Module type: IOM12B; monitoring is active  
    Shelf status: normal condition
    SES Configuration, shelf 1:
     logical identifier=****
     vendor identification=NETAPP  
     product identification=DS212-12
     product revision level=0141
     
Power Supply installed element list: 2; with error: none
    Power Supply information by element:
      [1] Serial number: <N/A>  Part number: <N/A>
          Type: <N/A>
          Input voltage: <N/A>
          Firmware version: <N/A>  Swaps: 0
      [2] Serial number: PST094242221387  Part number: 114-00148+G2
          Type: 98
          Input voltage: <N/A>
          Firmware version: 0200  Swaps: 0
    Voltage Sensor installed element list: 3, 4; with error: none
    Shelf voltages by element:
      [1] Unavailable
      [2] Unavailable
      [3] 5.01 Volts  Normal voltage range
      [4] 12.02 Volts  Normal voltage range
    Current Sensor installed element list: 3, 4; with error: none
    Shelf currents by element:
      [1] Unavailable
      [2] Unavailable
      [3] 2260 mA  Normal current range
      [4] 3240 mA  Normal current range
    Cooling Unit installed element list: 3, 4; with error: none
    Cooling Units by element:
      [1] Unavailable
      [2] Unavailable
      [3] 7020 RPM
      [4] 7050 RPM

  • Despite rebooting the BMC, replacing the PSU, and reseating the IOM, the shelf PSU alert persists.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.