DISK REDUNDANCY FAILED for one shelf due to faulty IOM
Applies to
- FAS8300
- DS212C
- IOM12B
Issue
- AutoSupport trigger subject
HA Group Notification (DISK REDUNDANCY FAILED) ERROR. SYSCONFIG-Ashows only one shelf missing disk:
Path using IOM A:
->missing shelf 1 all disk
02.0 : netapp x336_ttcre04ta07 na04 3807.8gb 520b/sect
....
shelf 1: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
shelf 2: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
shelf 3: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
shelf 4: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
shelf 5: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
shelf 6: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
Path using IOM B:
01.0 : netapp x336_ttcre04ta07 na04 3807.8gb 520b/sect
....
01.11: netapp x336_ttcre04ta07 na04 3807.8gb 520b/sect
02.0 : netapp x336_ttcre04ta07 na04 3807.8gb 520b/sect
shelf 1: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
shelf 2: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
shelf 3: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
shelf 4: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
shelf 5: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
shelf 6: ds212-12 firmware rev. iom12b a: 0130 iom12b b: 0130
SAS-EXPANDER-MAPdoesn't show IOM version.
Level 1: WWN 500a09800869dbf1, ID 1, Serial Number ' XXXXXXXXXXX', Product 'DS21212IOM12 ', Rev'0?1', Slot A