Applies to

  • FAS8300
  • DS460C disk shelves

Issue

  • The "monitor.shelf.fault" event is due to Temp Sensor 5 on shelf 0 reporting "OT FAILURE":

Enclosure Status: critical
Channel: 0a
Shelf: 0
Shelf Type: DS460-12
Product Serial Number: 111111111111
Module Type: IOM12B

Temperature Sensors:
Element Status Status Bytes Status Descriptions
1: OK 01,00,29,00
2: OK 01,00,2D,00
3: OK 01,00,2D,00
4: OK 01,00,2D,00
5: CRITICAL 02,00,4C,0C OT WARNING, OT FAILURE
6: OK 01,00,2D,00

Channel: 0a
Shelf: 0
SES device path: local access: 0a.00.99
Module type: IOM12B; monitoring is active
Shelf status: critical condition
SES Configuration, shelf 0:

Shelf temperatures by element:
[1] 21 C (69 F) (ambient) Normal temperature range
[2] 25 C (77 F) Normal temperature range
[3] 25 C (77 F) Normal temperature range
[4] 25 C (77 F) Normal temperature range
[5] 56 C (132 F) Overtemperature failure!
[6] 25 C (77 F) Normal temperature range

  • Sensor 5 is PSU 2 Inlet

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.