CriticalFruNotPresentAlert is reported on a single node in the HA pair
Applies to
- ONTAP 9
- FAS/AFF Systems
Issue
- The following alerts are seen in the event logs:
[Node-01: cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = PSU1 FRU#95210XXXXXX raised by monitor chassis
[Node-01: cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = PSU2 FRU#95210XXXXXX raised by monitor chassis
- The output of
system health alert showcommand reports the same alert:
Cluster1::*> system health alert show
Node: Node-01
Alert ID: CriticalFruNotPresentAlert
Resource: PSU2 FRU#95210XXXXXX
Severity: Critical
Indication Time: Sat May 13 13:46:10 2023
Suppress: false
Acknowledge: false
Probable Cause: PSU2 FRU is not present in the chassis 95210XXXXXX.
The nodes in this chassis are Node-01.
Possible Effect: The nodes in the chassis might not function
effectively or redundancy might be lost.
Corrective Actions: 1. Plug in PSU2 FRU correctly into the slot.
2. Refer to the Hardware specification guide for more information on the position of the field-replaceable unit (FRU) and ways to check or replace it.
3. Contact support personnel if the alert persists.
- The missing FRUs are reported as unreachable by the affected node:
Cluster1::*> system controller fru show
Node FRU Name Subsystem Status
------------------ ---------------------------- ------------------ -----------
Node-01 PSU1 FRU Environment unreachable
Node-01 PSU2 FRU Environment unreachable
- The same FRUs report normal status from the partner node:
Node FRU Name Subsystem Status
------------------ ---------------------------- ------------------ -----------
Node-02 PSU1 FRU Environment ok
Node-02 PSU2 FRU Environment ok
- The SP/BMC on the affected node is already on the latest version.
- The details may not be shown for the missing FRU under
system chassis fru show
::> system chassis fru show
Chassis ID FRU Type State Nodes Sharing the FRU
------------------- ---------- -------- ----------- -----------------------
95210XXXXXXXX Fan2 fan GOOD Node-02
95210XXXXXXXX Fan2 fan GOOD Node-01
95210XXXXXXXX Fan1 fan
- Performing takeover/giveback of the node does not help.