Cluster port link down/up repeats from FAS8300 platform

Views:
621
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

FAS8300

Issue

  • Cluster port link down/up repeats from both cluster ports
[?] Sun Aug 06 05:22:50 [node01: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0c: Link down, check cable.
[?] Sun Aug 06 05:22:50 [node01: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0d: Link down, check cable.
[?] Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node01, port e0c.
[?] Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0c on node node01 has gone down unexpectedly.
[?] Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node01, port e0d.
[?] Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0d on node node01 has gone down unexpectedly
[?] Sun Aug 06 05:22:53 [node01: mgmt_port_link_status_poll: netif.linkUp:info]: Ethernet e0d: Link up.
[?] Sun Aug 06 05:22:53 [node01: mgmt_port_link_status_poll: netif.linkUp:info]: Ethernet e0c: Link up.
[?] Sun Aug 06 05:22:56 [node01: vifmgr: vifmgr.portup:notice]: A link up event was received on node node01, port e0d.
[?] Sun Aug 06 05:22:56 [node01: vifmgr: vifmgr.portup:notice]: A link up event was received on node node01, port e0c.
 
=-=-=-=-=-= Sun Aug 06 2023, 05:24:51  EMS-LOG-FILE.GZ 2 lines
Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node01, port e0c.
Sun Aug 06 05:22:53 [node01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node01, port e0d.
 
=-=-=-=-=-= Sun Aug 06 2023, 05:24:51  EMS-LOG-FILE.GZ 2 lines
Sun Aug 06 05:22:53 [node02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node02, port e0c.
Sun Aug 06 05:22:53 [node02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node02, port e0d.
 
  • The HA ports e0a and e0b may also experience a Link down simultaneously.
[kernel: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
[kernel: netif.linkDown:info]: Ethernet e0b: Link down, check cable.
[kernel: netif.linkDown:info]: Ethernet e0c: Link down, check cable.
[kernel: netif.linkDown:info]: Ethernet e0d: Link down, check cable.
 
sysconfig -a
 
NetApp Release 9.7P7: Thu Aug 27 16:59:02 EDT 2020
                Model Name:         FAS8300
 
slot 0: 40G/100G Ethernet Controller CX5
e0c MAC Address:    xx:xx:xx:xx:xx:xx (auto-100g_cr4-fd-up)
    QSFP Vendor:         Amphenol
    QSFP Part Number:    112-00595
    QSFP Serial Number:  APFxxxxxxxxxxx
e0d MAC Address:    xx:xx:xx:xx:xx:xx (auto-100g_cr4-fd-up)
    QSFP Vendor:         Amphenol
    QSFP Part Number:    112-00595
    QSFP Serial Number:  APFxxxxxxxxxxx
Device Type:        CX5 PSID(NAP0000000005)
Firmware Version:   16.26.4012
 
  • Switchless configuration
Enable Switchless Cluster: true
 
  • Cluster cable reseat and replacement could not clear this issue

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.