"CHASSIS FAN FRU FAILED: Multiple fans have failed " reported on one node
Applies to
Issue
- One node report
HA Group Notification (CHASSIS FAN FRU FAILED: Multiple fans have failed) ERRORfrequently. SP-LATEST-IPMIshow PSU1 and PSU2 sensor not available.
PSU1 5V not_available -- mV -- -- -- --
PSU1 12V not_available -- mV -- -- -- --
PSU1 5V Curr not_available -- mA -- -- -- --
PSU1 12V Curr not_available -- mA -- -- -- --
PSU1 Fan 1 not_available -- RPM -- -- -- --
PSU1 Fan 2 not_available -- RPM -- -- -- --
PSU1 Inlet Temp not_available -- C 0 C 5 C 57 C 62 C
PSU1 Hotspot Temp not_available -- C 0 C 5 C 90 C 100 C
PSU2 5V not_available -- mV -- -- -- --
PSU2 12V not_available -- mV -- -- -- --
PSU2 5V Curr not_available -- mA -- -- -- --
PSU2 12V Curr not_available -- mA -- -- -- --
PSU2 Fan 1 not_available -- RPM -- -- -- --
PSU2 Fan 2 not_available -- RPM -- -- -- --
PSU2 Inlet Temp not_available -- C 0 C 5 C 57 C 62 C
PSU2 Hotspot Temp not_available -- C 0 C 5 C 90 C 100 C
PSU_FAN not_available --
SYSCONFIG -Ashow 0b port missing all the shelf.
slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
Temperature: Not Available
Phy State: [4] Disabled
[5] Disabled
[6] Disabled
[7] Enabled, 12.0 Gb/s
- Motherboard reseat doesn't resolve the issue.