Alert LED turned ON a Shelf without any other observed fault or DC UNDER VOLTAGE messages
Applies to
- DS2246
- DS4486
- DS4246
- DS4243
- NS224
- Data ONTAP
Issue
- Disk Shelf reports error message
DC UNDER VOLTAGE, the LED is ON
without any other indicating LED, or any failure message. - Depending on the version of Data ONTAP the system behaviour is different.
BUG ID
|
Symptom Notes
|
Fixed in
|
---|---|---|
DC Undervoltage No errors reported in EMS
|
8.2.4 and 8.3.1
|
|
DC Undervoltage constant EMS reporting
|
8.2.4, 8.3.1P1, and 8.3.2RC2
|
|
DC Undervoltage EMS report every 6 hrs
|
8.3.2RC1
|
- The
storage show fault
output will indicate 'No faults found in storage subsystem'.
However, the "storage show fault –v" will display the following status:
Power Supplies:
Element Status Status Bytes Status Descriptions
1: OK 01,00,04,A0 DC UNDER VOLTAGE, RQSTED ON
2: OK 01,00,00,A0 RQSTED ON