Skip to main content
NetApp Knowledge Base

ActiveIQ risk shows shelf component is in a non-normal state

Views:
120
Visibility:
Public
Votes:
0
Category:
disk-drives
Specialty:
hw
Last Updated:

Applies to

  • DS212C shelf
  • Active IQ

Issue

  • Active IQ Risk:

A shelf component is in a non-normal state.
Potential Impact:
Depending on which component is in a non-normal state, the result can lead to an unplanned outage.
Details:
Shelf 0 on adapter 0a is reporting errors on the following component(s); Bay 4.

 

  • SAS-EXPANDER-PHY-STATE section of Autosupport:
Expander phy state on 0a.0 (NETAPP  :DS21212IOM12E    SHJSG2301000095): 
                              Pwr         Invald Disprt Loss   Phy    CRC    Phy                    
                          Pwr Ccl Rsv Rls DWord  Error  Sync   Reset  Error  Change SATA            
PHY/BAY STATE             ON  Cnt Cnt Cnt Count  Count  Count  Prob   Cnt    Cnt    Affiliation     
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
 0/P0:0 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      5      ----------------
 1/P0:1 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      5      ----------------
 2/P0:2 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      5      ----------------
 3/P0:3 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      5      ----------------
 4/P1:0 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      1      ----------------
 5/P1:1 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      1      ----------------
 6/P1:2 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      1      ----------------
 7/P1:3 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      1      ----------------
 8/0    12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
 9/1    12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
10/2    12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
11/3    12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
12/4    6.0 Gb/s          YES 0   0   0   0      0      0      0      0      1      ----------------  <<<< bay4 disk rate only 6Gb/s
13/5    12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
14/6    12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
15/7    12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
16/8    12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
17/9    12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
18/10   12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
19/11   12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
20/12   Disabled/NODRV    --- 0   0   0  
21/13   Disabled/NODRV    --- 0   0   0  
22/14   Disabled/NODRV    --- 0   0   0  
23/15   Disabled/NODRV    --- 0   0   0  
24/16   Disabled/NODRV    --- 0   0   0  
25/17   Disabled/NODRV    --- 0   0   0  
26/18   Disabled/NODRV    --- 0   0   0  
27/19   Disabled/NODRV    --- 0   0   0  
28/20   Disabled/NODRV    --- 0   0   0  
29/21   Disabled/NODRV    --- 0   0   0  
30/22   Disabled/NODRV    --- 0   0   0  
31/23   Disabled/NODRV    --- 0   0   0  

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.