SVMDR fails with "Unable to generate baseline for table netgroup_xclus_file_repl"
Applies to
- SVM Disaster Recovery (SVMDR)
- Configuration Replication Service (CRS)
- netgroups
Issue
- A new SVMDR relationship fails to initialize
- On the destination system, this error can be found in both snapmirror show output and the snapmirror_audit log:
Failed to generate configuration baseline. Reason: CRS stream operation failed. Reason: Unable to generate baseline
for table netgroup_xclus_file_repl.
- On the SVMDR source system, messages similar to these can be found in the mgwd log:
Failed to become an official package distributor for netgroup-file-vsid-[vserver ID]:latest. Reason: the requested package edition does not exist.
read_rdb_counter fopen failed for path /mroot/etc/cluster_config/vserver/.[vserver ID]/config/name_services//etc/netgroup . Errno is 2