Volume failed to convert to Flexgroup with disallow option FSOPTIONS 0x100000000000000
Applies to
- ONTAP 9.14.1P2 to 9.14.1P7
- FlexGroup
Issue
The customer run the command of "
vol conversion start" to failed with following errors:Cluster-01::*> run local vol options testnosnap=off, nosnapdir=off, minra=off,no_atime_update=off, nvfail=off,ignore_inconsistent=off, snapmirrored=off,create_ucode=on,convert_ucode=on,maxdirsize=327680, schedsnapname=create_time,fs_size_fixed=off, guarantee=none,svo_enable=off, svo_checksum=off,svo_allow_rman=off, svo_reject_errors=off,no_i2p=off,fractional_reserve=0, extent=off,try_first=volume_grow,sis_logging=off, read_realloc=off,snapshot_clone_dependency=off,dlog_hole_reserve=off, batched_free_log_cap=1.50%, space_slo=none,zombie_reclamation_priority=auto, dir_holes=on,logical_space_enforcement=off,logical_space_reporting=offCluster-01::*> vol conversion start -vserver SVM-B -volume test Warning: * After the volume is converted to a FlexGroup, it will not be possible to change it back to a flexible volume. * Converting flexible volume "test" in Vserver "SVM-B" to a FlexGroup will cause the state of all Snapshot copies from the volume to be set to "pre-conversion". Pre-conversion Snapshot copies cannot be restored. * Converting the volume to a FlexGroup will not add additionalresources for capacity. After converting, use the "volume expand" command to add resources.Do you want to continue? {y|n}: y[Job 685] Renaming volume back to original name. Error: command failed: [Job 685] Job failed: Volume conversion failed. Reason: Volume with DSID 1055 cannot be converted to a FlexGroup volume because its configuration is not supported by FlexGroup volumes. Contact technical support for further assistance.