Issue

  • Ping/SSH does not work on CN1610 cluster switch, as the service port is not properly configured with an IP address:

(Switch)#show serviceport

Interface Status............................... Up
IP Address..................................... 0.0.0.0
Subnet Mask.................................... 0.0.0.0
Default Gateway................................ 0.0.0.0

IPv6 Administrative Mode....................... Enabled
IPv6 Prefix is ................................ fe80::2a0:94ff:feef:560e/64
Configured IPv4 Protocol....................... None
Configured IPv6 Protocol....................... None
IPv6 AutoConfig Mode........................... Disabled
Burned In MAC Address.......................... 00:A0:96:EF:56:0E

  • Service port configuration conflicts with the configured IP address in the switch.

(Switch)#serviceport ip 172.70.10.10 255.255.255.0 172.70.10.1

IP Address/Netmask entered conflicts with the configured IP Address/Netmask of
the switch.

  • It can be found that the same IP address is assigned to the network port.

(Switch)#show network

Interface Status............................... Up
IP Address..................................... 172.70.10.10
Subnet Mask.................................... 255.255.255.0
Default Gateway................................ 172.70.10.1

IPv6 Administrative Mode....................... Enabled
IPv6 Prefix is ................................ fe80::2a0:94ff:feef:560e/64
Burned In MAC Address.......................... 00:A0:98:EF:58:0D
Locally Administered MAC address............... 00:00:00:00:00:00
MAC Address Type............................... Burned In
Configured IPv4 Protocol....................... None
Configured IPv6 Protocol....................... None
IPv6 AutoConfig Mode........................... Disabled
Management VLAN ID............................. 1

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.