Data outage during switchless to switched conversion due to improper operations
Applies to
- ONTAP 9
- Cisco Nexus 9336C-FX2
- Switchless to switched cluster conversion
Issue
- Data outage is experienced during the procedure after cabling cluster ports to cluster switches
- All data LIFs in down state.
- VifMgr is offline and OOQ according to vifmgr log.
Tue Jan 10 2023 13:39:29 +08:00 [kern_vifmgr:info:6271] A [src/rdb/TM.cc 1760 (0x80c241800)]: _triggerOnlineStatusCallback: FAILOVER rdb: Local unit VifMgr offline
Tue Jan 10 2023 13:39:29 +08:00 [kern_vifmgr:info:6271] Notice: online_status_callback: RDB unit is offline
Tue Jan 10 2023 13:40:34 +08:00 [kern_vifmgr:info:6271] [0x80c244500] [EventMgr::unitOffline] Setting VifMgr operational status as OOQ
Tue Jan 10 2023 13:40:34 +08:00 [kern_vifmgr:info:6271] [0x80c244500] [FailoverMgr::localNodeDown] VifMgr on node f68pfs452n2 is now out of quorum.