“SwitchIfDead_Alert” reported After Replacement of Cluster Switch and ONTAP upgrade
Applies to
- ONTAP 9
- FAS/AFF/ASA Systems
- Cisco Cluster Switches
Issue
- After replacing cluster switches and performing a firmware upgrade, the ONTAP command
system health subsystem showdisplays the following:'syshealthsubshow' shows switchHealthUnknown - Additionally, the following persistent health alerts are reported:
Node::> system health alert showNode: Node-01Alert ID: SwitchIfDead_AlertResource: Ethernet1/1/1Severity: MajorIndication Time: <timestamp>Suppress: falseAcknowledge: falseProbable Cause: The interface Cluster-sw2(FOCXXXXXXXX)/Ethernet1/1/1 is up, but has not passed unicast traffic for twelve consecutive polling intervals.Possible Effect: The lack of transmit or receive traffic reported bythe switch can indicate issues with port-level orswitch-level data packet forwarding.Corrective Actions: 1) Check interface counters and neighbor discovery information to verify the port's activity.2) Check cluster and switch health status. - This alert seen for multiple ports, and persists even after clearing and re-adding the switches in CSHM