Skip to main content
NetApp Knowledge Base

Brocade FC port offline with No_Sync state due to loose/faulty cable

Views:
705
Visibility:
Public
Votes:
4
Category:
fabric-interconnect-and-management-switches
Specialty:
san
Last Updated:

Applies to

  • Brocade FC Switch
  • Fabric OS (FOS)

Issue

  • Brocade fiber channel port is in No_sync , Disabled state under switchshow output: 

/fabos/bin/switchshow :
Index Slot Port Address Media  Speed        State    Proto
============================================================

228 11 20 6be400 id N32 No_Sync FC Disabled (Port Throttled)

 

  • Porterrshow reports link fail and loss_sync errors.

/fabos/cliexec/porterrshow :
          frames        enc     crc     crc     too     too     bad     enc    disc    link    loss    loss    frjt    fbsy     c3timeout     pcs      uncor
        tx       rx      in     err     g_eof   shrt    long    eof     out    c3      fail    sync    sig                      tx      rx      err     err
228:   10.5g   16.2g    0       0       0       0       0       0       0       0      14      15       0       0       0       0       0       0       0

 

  • sfpshow reports low Rx power :

=============
Slot  4/Port  24:
=============

RX Power:    -20.2   dBm (9.6  uW)
TX Power:    -0.6    dBm (879.9 uW)

 

  • Fabriclog output reported link failures:
Switch 0; Sun Jan 29 12:04:25 2023 IST (GMT+5:30)
12:04:25.839042 SCN Port Offline;rsn=0x3,g=0xc44            D2,P0  D2,P0  228   NA
12:04:25.839049 *Removing all nodes from port               D2,P0  D2,P0  228   NA
22:21:42.632387 SCN LR_PORT(0);g=0xc44                      D2,P0  D2,P0  228   NA
22:21:42.666236 SCN Port Online; g=0xc44,isolated=0         D2,P0  D2,P1  228   NA
22:21:42.666376 Port Elp engaged                            D2,P1  D2,P0  228   NA
22:21:42.666389 *Removing all nodes from port               D2,P0  D2,P0  228   NA
22:21:42.666643 SCN Port F_PORT                             D2,P1  D2,P0  228   NA
22:27:49.180108 SCN Port Offline;rsn=0x10004,g=0xc46        D2,P0  D2,P0  228   NA
22:27:49.180115 *Removing all nodes from port               D2,P0  D2,P0  228   NA
22:29:29.082525 SCN LR_PORT(0);g=0xc46                      D2,P0  D2,P0  228   NA
22:29:29.114287 SCN Port Online; g=0xc46,isolated=0         D2,P0  D2,P1  228   NA
22:29:29.114347 Port Elp engaged                            D2,P1  D2,P0  228   NA
22:29:29.114358 *Removing all nodes from port               D2,P0  D2,P0  228   NA
22:29:29.114583 SCN Port F_PORT                             D2,P1  D2,P0  228   NA
  • Verify if the switch end sfp Tx and Rx power are within the recommended range.

  • Low Rx power indicates an issue upstream to the switch, faulty hardware, including cable and end device sfp.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.